Description
Alarm test function
This test function can be used to check whether an internally or externally connected alarm system is functioning correctly. The appliance’s refrigeration performance is not affected by this test.
Pharmaceutical storage: DIN 58345
DIN stands for ‘Deutsches Institut für Normung’ (German Institute for Standardization). This Institute’s specialist bodies define industry standards. DIN 58345 relates to pharmaceutical refrigerators that are used to store pharmaceuticals at operating temperatures of between 2°C and 8°C. DIN 58345 currently reflects the latest technological advances and establishes precisely formulated requirements in relation to pharmaceutical refrigerators.
Digital temperature display
The digital temperature display indicates the refrigerator’s interior temperature to the exact degree. This can be easily read from the outside to give users immediate information and without the need to open the appliance.
Forced air cooling
Highly efficient fans cool freshly stored produce quickly and maintain an even refrigeration temperature throughout the interior.
Efficient refrigeration system
Liebherr guarantees the outstanding quality of its refrigeration systems through expertise derived from decades of experience in the refrigeration technology sector, and through continuous research and development. By employing only premium-quality compressors, condensers, evaporators and other refrigeration components the energy consumption and operating costs of Liebherr appliances are significantly reduced.
LED interior lighting
All laboratory fridges with a glass door feature LED lighting, which evenly illuminates the entire interior so that stored products can be easily seen and quickly accessed. This lighting can be switched off, if required.
A serial bus interface can be used to connect appliances to an external monitoring system. If there is no monitoring system that can be connected via the interface available, an interface converter retrofitting kit (which connects with a PC or laptop) can be obtained as an optional accessory. The bus interface can be used to serially connect and network up to 20 appliances. Temperature and alarm details can be documented and archived using Liebherr’s Temperature Monitoring software.
The integrated temperature alarm indicates if the lower or upper alarm thresholds have been breached. It uses both acoustic and visual signals to provide maximum security for goods that have been stored.
All laboratory refrigerators and freezers are tested at the state-of-the-art Liebherr development facilities according to procedure EN 60068-3 for measuring temperature stability. This involves measuring the temperature at nine different points in the appliance interiors.
Product group output channels | Pharmacy refrigerator with Comfort controller |
---|---|
GTIN | 9005382238356 |
Energy consumption in 24h | 1.188 kWh / 24h |
---|---|
Noise level | 48 dB |
Net capacity, total | 201 l |
Gross capacity, total | 386 l |
Refrigerant | R 600a |
Voltage | 220-240 V ~ |
Frequency | 50 Hz |
Connection rating | 1.5 A |
Product dimensions (H/W/D) | 184 / 60.1 / 61.8 cm |
---|---|
Insulation | 40 – 40 mm |
Weight (with packaging) | 104.00 kg |
Weight (without packaging) | 98.00 kg |
Control | Electronic control system |
---|---|
Control unit | Buttons |
Malfunction: Warning signal | optical and acoustical |
potential-free contact | ✔ |
Power failure alarm | immediately upon power failure for min. 12h |
Maximum fluctuation | 1.5 °C |
Gradient | 3.5 °C |
SmartMonitoring | Vorgerüstet |
Side wall material | steel |
---|---|
Colour | white |
Door/Cover material | Double-glazed door |
Lock | fitted |
Self-closing door | ✔ |
Door hinges | right interchangeable |
Material of interior containers | Plastic white |
Type of castors | — |
Door design | HardLine |
Handle | Ergonomic slimline handle with opening mechanism |